Testo 445 - Climate Measuring Instrument [SKU 0560 4450] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo 445 - Climate Measuring Instrument [SKU 0560 4450] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors Testo 445 - Climate Measuring Instrument [SKU 0560 4450] Air Flow Pressure / Air Flow / Manifolds / Gas Detectors


testo 445 - Climate Measuring Instrument
 
  • Multi-function climate measuring instrument: measure up to 6 measurement parameters at the same time
  • Internal reading memory for up to 3,000 readings
  • Automatic allocation of the duct cross-section to the measuring location (max. 99 measuring locations)
  • Automatic mean value calculation and determination of the volume flow
You can keep a close eye on indoor air quality with the testo 445 climate measuring instrument: the allrounder can measure up to 6 parameters (with the appropriate probe), which can help you make a professional assessment of indoor air quality. The climate measuring instrument therefore supports you in adjusting and checking ventilation and air conditioning systems.
This meter uses a sensor to start up.
 
 
Product Description
 
Ventilation and air conditioning systems are used more and more frequently to ensure user independent fresh air supply and thermal comfort in buildings. The testo 445 climate measuring instrument helps you check the system is functioning properly and operating efficiently. This is because the measuring instrument can determine all the relevant measurement parameters for you.
 
 
testo 445 climate measuring instrument: an overview of the advantages
 
The testo 445 climate measuring instrument has two inputs for connecting external probes (which can be ordered separately). At Testo, you have a large selection of suitable probes for the testo 445 climate measuring instrument. Depending on which probe you decide on, you can determine the following parameters:
  • Air velocity (in ventilation ducts, at duct outlets and on extractors)
  • Volume flow
  • Indoor air quality (CO2)
  • Temperature
  • Relative air humidity
  • Dew point
  • Absolute humidity
  • Degree of humidity
  • Enthalpy
  • Pressure
  • CO in indoor air
Further practical features of the climate measuring instrument: its internal memory records up to 3,000 readings. The automatic allocation of the duct cross-section is also particularly useful. This means you can save the measurement data so that it is linked to the measuring location (up to 99 measuring locations). The mean value, the last measured value and the min./max. values can be displayed simply by pressing a key.

As optional accessories for the climate measuring instrument, we recommend you get the testo fast printer to print data out directly at the measuring location and the ComSoft software for convenient data analysis on the PC.
 
 
Delivery Scope
 
testo 445 climate measuring instrument, including battery and calibration protocol.
 
 
Technical Data
 

Temperature - NTC
Measuring range -50 to +150 °C
Accuracy ±0.5 % of mv (+100 to +150 °C)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (-50 to -25.1 °C)
±0.4 °C (+75 to +99.9 °C)
Resolution 0.1 °C (-50 to +150 °C)
 
Temperature - TC Type K (NiCr-Ni)
Measuring range -200 to +1370 °C
Accuracy ±0.3 °C (-60 to +60 °C)
±(0.2 °C + 0.5 % of mv) (Remaining Range)
Resolution 0.1 °C (-200 to +1370 °C)
 
Temperature - TC Type J (Fe-CuNi)
Measuring range -200 to +1000 °C
Accuracy ±0.5 °C or ±0.5 % of mv
Resolution 0.1 °C (-200 to +1000 °C)
 
Humidity - Capacitive
Measuring range 0 to 100 %RH
Accuracy See probe data
Resolution 0.1 %RH (0 t1 +100 %RH)
 
Velocity - Vane anemometer
Measuring range 0 to 60 m/s
Accuracy See probe data
Resolution 0.01 m/s
 
Ambient CO
Measuring range 0 to 10000 ppm 
0 to 1 Vol.% 
Accuracy ±(100 ppm + 3 % of mv) (5000 to 10000 ppm)
±(500 ppm + 2 % of mv) (1 to 5000 ppm)
Vol %: see probe data
Resolution 1 ppm
0.0001 Vol.%
 
Velocity - Thermal anemometer
Measuring range 1 to +20 m/s
Accuracy See probe data
Resolution 0.01 m/s (1 to 10 m/s)
0.1 m/s (10.1 to 20 m/s)
 
Ambient CO
Measuring range 0 to 500 ppm 
Accuracy ±5 % of mv (100 to 500 ppm)
±5 ppm (0 to 100 ppm)
Resolution 1 ppm (0 to 500 ppm)
 
Pressure measurement
Measuring range See pressure probes
Accuracy ±0.001 hPa (Probe 0638 1345)
±0.001 hPa (Probe 0638 1445)
±0.01 hPa (Probe 0638 1545)
±1.0 hPa (Probe 0638 1645)
 
General technical data
Dimensions 215 x 68 x 47 mm
Operating temperature 0 to +50 °C
Housing ABS
Warranty 2 years
Battery type 9V block battery, 6F22
Battery life 45 h
Display type LCD
Display size 4 lines
Data transfer RS232
Memory 3,000 measuring values
Storage temperature -20 to +70 °C
Weight 255 g
 
 
Downloads
 
Product Brochures

Product brochure testo 445  (PDF, 1.300 KB)
 
Manuals

Instruction manual testo 445  (PDF, 1.7 MB)
Overview of controls testo 445  (PDF, 72.2 kB)
 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter